{"product_id":"original-mebay-dc92dr-replaced-by-dc92dr-mkii-controller-panel-board-generator-auto-start-control-unit-module","title":"Original Mebay DC92DR Replaced By DC92DR MKII Controller Panel Board Generator Auto Start Control Unit Module","description":"\u003cdiv class=\"detailmodule_dynamic\"\u003e\n\u003cspan style=\"font-size:22px;\"\u003e\u003cstrong\u003eOriginal Mebay DC92DR replaced by DC92DR MKII Generator Controller RS485 CAN interface monitoring Control Board\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003cbr\u003e\n\u003cspan style=\"font-size:14px;\"\u003e\u003cstrong\u003eOverview：\u003c\/strong\u003e\u003cbr\u003e\n  This series controller is specialized for Diesel \/ Gasoline \/ Gas Genset Start, Stop, Parameters monitoring, faults-checking as well as data setting.\u003cbr\u003e\n  4.3inch colorful LCD screen display with brand new UI design is adapted in this controller that the relative failures can be displayed directly. All the parameters can be displayed by simulated indicators and words. Besides, LCD screen can display various faults in the same time that the genset will be stopped once it can’t work smoothly.\u003cbr\u003e\n  There are Chinese\/English interface options, more language can be set according to user’s request. All the parameters can be configured through the front face buttons or use programmable interface by RS485 or USB to adjust via PC. It can be widely applied for all kinds of auto control system of gensets.\u003c\/span\u003e\n\u003ch4\u003e\u003cspan style=\"font-size:14px;\"\u003e\u003cstrong\u003eWide Application Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\n\u003cp\u003e\u003cspan style=\"font-size:14px;\"\u003eLarge silent single diesel generator control cabinet, data center backup AMF genset, commercial building peak shaving standby power, communication base station automatic transfer power equipment, marine large single auxiliary generator set, mine off-grid industrial power supply, municipal emergency power station, generator repair shops and large power distribution engineering projects requiring ECU engine data reading and remote centralized cloud monitoring.\u003c\/span\u003e\u003c\/p\u003e\n\n\u003ch4\u003e\u003cspan style=\"font-size:14px;\"\u003e\u003cstrong\u003eProduct Specifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\n\u003cul style=\"list-style-type: disc;\"\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003eBrand: Mebay\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003eModel: DC92DR MK3\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003eCore Function: Flagship AMF auto mains failure generator controller with RS485 remote communication + CAN J1939 ECU reading, substitute imported DeepSea DSE7320\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003eDC Power Supply: DC9V~36V wide voltage universal for 12V\/24V generator batteries\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003eAC Sampling: Dual-way mains+generator three-phase voltage simultaneous monitoring, auto 50\/60Hz frequency recognition\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003eCommunication Interfaces: Front USB local debug, rear isolated RS485 Modbus RTU, CANbus J1939 engine ECU data reading\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003eDisplay: 4.3-inch colorful TFT multi-language LCD dashboard\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003ePanel Cutout Size: 220 × 160 mm, overall dimension 241 × 177 × 45 mm\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003eWeight: 1kg\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003eFront Panel Protection Grade: IP54 dustproof \u0026amp; waterproof with silicone sealing gasket\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003eOperating Temperature: -25℃ ~ +65℃\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003eWarranty: 12 months genuine factory warranty\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003e\u003cspan style=\"font-size:14px;\"\u003e\u003cstrong\u003eCommon Equipment Failures Solved\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\n\u003cul style=\"list-style-type: disc;\"\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003eGenerator cannot auto start after mains power loss: Mains voltage sampling wiring loose, AMF delay start parameter misconfigured\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003eDT1000 cloud platform cannot receive genset running data: RS485 A\/B wiring reversed, WIFI network password error or Ethernet cable disconnection\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003eOnboard relay burned when driving glow plug: Onboard contact capacity limited to 16A, install external Hongfa HAT700BI 70A heavy relay for current amplification\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003eLaptop cannot connect controller via RS485 communication: Use SG72A USB-RS485 adapter, confirm matching baud rate without wiring reversal\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003eNo engine data displayed on CAN J1939 port: CAN-H\/CAN-L wiring reversed, engine ECU communication protocol mismatch\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003eFrequent reverse power protection shutdown during ATS switching: Mains-generator phase angle threshold parameter set too sensitive\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003eOld DSE7320 panel damaged and need replacement: DC92DR MK3 same mounting size and terminal definition, direct swap without cabinet wiring modification\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n","brand":"PEMP Generator Parts Store","offers":[{"title":"DC92DR \/ CHINA","offer_id":45817574293670,"sku":"DC92DR","price":248.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0659\/1125\/9302\/files\/Sb39a42eb5bde401d81b95218bbc9601fQ.webp?v=1726825918","url":"https:\/\/www.pempstore.com\/products\/original-mebay-dc92dr-replaced-by-dc92dr-mkii-controller-panel-board-generator-auto-start-control-unit-module","provider":"PEMP Generator Parts Store","version":"1.0","type":"link"}