{"product_id":"original-deif-agc-4-repalce-by-agc-4-mkii-automatic-genset-controller-genset-control-module","title":"Original DEIF AGC-4 Repalce By AGC-4 MKII Automatic Genset Controller Genset Control Module","description":"\u003cp\u003e\u003cspan style=\"font-size:24px\"\u003e\u003cstrong\u003eOriginal DEIF AGC-4 Automatic genset controller Genset Control Module\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cspan style=\"font-size:18px;\"\u003e\u003cstrong\u003eOverview:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003cspan style=\"font-size:16px;\"\u003eThe AGC-4 is a configurable controller that can be used in applications ranging from a single controller for one genset, to complete power management systems. The controller contains the 3-phase measuring circuits and all the functions required to protect and control a genset.The controllers can also be used to protect and control mains connections, tie breakers, and bus tie breakers.\u003cbr\u003e\n\u003cbr\u003e\nUp to 40 AGCs can be connected in a power management system. AGC-4 can also be combined with AGC 150 (up to 32), ASC-4 (Solar and\/or Battery), and\/or ALC-4 (Automatic Load Controller). With extended power management, a system can manage up to 992 gensets (each controlled by AGC-4).\u003cbr\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cspan style=\"color:#e67e22;\"\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003cspan style=\"color:#e74c3c;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: 15px; font-style: normal; font-variant-ligatures: normal; font-variant-caps: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: start; text-indent: 0px; text-transform: none; widows: 2; word-spacing: 0px; -webkit-text-stroke-width: 0px; white-space: normal; background-color: rgb(255, 255, 255); text-decoration-thickness: initial; text-decoration-style: initial; text-decoration-color: initial; float: none; display: inline !important;\"\u003eThe AGC-4 is being replaced by the AGC-4 Mk II in DEIF's product programme. Spare part units can still be delivered, but it is recommended to use the replacement product AGC-4 Mk II instead.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\n \u003c\/p\u003e\n\n\u003ch2\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h2\u003e\n\n\u003cul style=\"list-style-type: disc;\"\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:16px;\"\u003eBrand: DEIF (Denmark)\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:16px;\"\u003eModel: AGC-4\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:16px;\"\u003eProduct Type: Automatic Generator Controller\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:16px;\"\u003eFunction: AMF, Synchronization, Paralleling, Load Sharing, Power Management, Generator Protection\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:16px;\"\u003eCommunication: CAN bus, RS485 Modbus RTU, USB, Ethernet TCP\/IP\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:16px;\"\u003eMount: DIN rail\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:16px;\"\u003eCompliance: UL, TÜV, multiple international grid codes\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:16px;\"\u003eApplicable Engine: Diesel \/ Gas generator, support Tier4 Final \/ Stage V engine \u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:16px;\"\u003eNet weight: 1.2kg\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:16px;\"\u003eWarranty: 12 months genuine factory warranty\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 data-v-24d9c7da=\"\" style='box-sizing: border-box; margin: 20px 0px 10px; padding: 0px; font-weight: 700; line-height: 1.1; -webkit-font-smoothing: antialiased; font-size: 30px; color: rgb(67, 67, 67); font-family: Inter, Arial, \"sans-serif\"; font-style: normal; font-variant-ligatures: normal; font-variant-caps: normal; letter-spacing: normal; orphans: 2; text-align: start; text-indent: 0px; text-transform: none; widows: 2; word-spacing: 0px; -webkit-text-stroke-width: 0px; white-space: normal; background-color: rgb(255, 255, 255); text-decoration-thickness: initial; text-decoration-style: initial; text-decoration-color: initial;'\u003e\u003cspan style=\"font-size:18px;\"\u003eFeatures\u003c\/span\u003e\u003c\/h2\u003e\n\n\u003cdiv data-v-24d9c7da=\"\" style='box-sizing: border-box; margin: 0px; padding: 0px; color: rgb(67, 67, 67); font-family: Inter, Arial, \"sans-serif\"; font-size: 18px; font-style: normal; font-variant-ligatures: normal; font-variant-caps: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: start; text-indent: 0px; text-transform: none; widows: 2; word-spacing: 0px; -webkit-text-stroke-width: 0px; white-space: normal; background-color: rgb(255, 255, 255); text-decoration-thickness: initial; text-decoration-style: initial; text-decoration-color: initial;'\u003e\n\u003cul style=\"box-sizing: border-box; margin: 0px; padding-inline-start: 2rem; -webkit-font-smoothing: antialiased; padding: 0px; list-style-type: none; color: rgb(67, 67, 67); text-decoration: none;\"\u003e\n\t\u003cli style=\"box-sizing: border-box; margin: 0px 0px 4px 10px; padding: 0px 0px 0px 3px; position: relative; font-size: 16px; color: rgb(67, 67, 67); text-decoration: none;\"\u003e\n\u003cspan style=\"font-size:18px;\"\u003e\u003cstrong\u003e· \u003c\/strong\u003e\u003c\/span\u003eUp to 32 gensets in one plant\u003c\/li\u003e\n\t\u003cli style=\"box-sizing: border-box; margin: 0px 0px 4px 10px; padding: 0px 0px 0px 3px; position: relative; font-size: 16px; color: rgb(67, 67, 67); text-decoration: none;\"\u003e\n\u003cspan style=\"font-size:18px;\"\u003e\u003cstrong\u003e· \u003c\/strong\u003e\u003c\/span\u003eThe intuitive, preprogrammed touch display saves you time and smoothes operation\u003c\/li\u003e\n\t\u003cli style=\"box-sizing: border-box; margin: 0px 0px 4px 10px; padding: 0px 0px 0px 3px; position: relative; font-size: 16px; color: rgb(67, 67, 67); text-decoration: none;\"\u003e\n\u003cspan style=\"font-size:18px;\"\u003e\u003cstrong\u003e· \u003c\/strong\u003e\u003c\/span\u003eFour general purpose PID regulators that control auxiliary systems\u003c\/li\u003e\n\t\u003cli style=\"box-sizing: border-box; margin: 0px 0px 4px 10px; padding: 0px 0px 0px 3px; position: relative; font-size: 16px; color: rgb(67, 67, 67); text-decoration: none;\"\u003e\n\u003cspan style=\"font-size:18px;\"\u003e\u003cstrong\u003e· \u003c\/strong\u003e\u003c\/span\u003eSynchronises up to 56 breakers in one plant\u003c\/li\u003e\n\t\u003cli style=\"box-sizing: border-box; margin: 0px 0px 4px 10px; padding: 0px 0px 0px 3px; position: relative; font-size: 16px; color: rgb(67, 67, 67); text-decoration: none;\"\u003e\n\u003cspan style=\"font-size:18px;\"\u003e\u003cstrong\u003e· \u003c\/strong\u003e\u003c\/span\u003eMultiple operating modes in one software\u003c\/li\u003e\n\t\u003cli style=\"box-sizing: border-box; margin: 0px 0px 4px 10px; padding: 0px 0px 0px 3px; position: relative; font-size: 16px; color: rgb(67, 67, 67); text-decoration: none;\"\u003e\n\u003cspan style=\"font-size:18px;\"\u003e\u003cstrong\u003e· \u003c\/strong\u003e\u003c\/span\u003eMulti-master power management\u003c\/li\u003e\n\t\u003cli style=\"box-sizing: border-box; margin: 0px 0px 4px 10px; padding: 0px 0px 0px 3px; position: relative; font-size: 16px; color: rgb(67, 67, 67); text-decoration: none;\"\u003e\n\u003cspan style=\"font-size:18px;\"\u003e\u003cstrong\u003e· \u003c\/strong\u003e\u003c\/span\u003eLoad-dependent start and stop\u003c\/li\u003e\n\t\u003cli style=\"box-sizing: border-box; margin: 0px 0px 4px 10px; padding: 0px 0px 0px 3px; position: relative; font-size: 16px; color: rgb(67, 67, 67); text-decoration: none;\"\u003e\n\u003cspan style=\"font-size:18px;\"\u003e\u003cstrong\u003e· \u003c\/strong\u003e\u003c\/span\u003eLoad management\u003c\/li\u003e\n\t\u003cli style=\"box-sizing: border-box; margin: 0px 0px 4px 10px; padding: 0px 0px 0px 3px; position: relative; font-size: 16px; color: rgb(67, 67, 67); text-decoration: none;\"\u003e\n\u003cspan style=\"font-size:18px;\"\u003e\u003cstrong\u003e· \u003c\/strong\u003e\u003c\/span\u003eEmulation for fast training and I\/O test\u003c\/li\u003e\n\t\u003cli style=\"box-sizing: border-box; margin: 0px 0px 4px 10px; padding: 0px 0px 0px 3px; position: relative; font-size: 16px; color: rgb(67, 67, 67); text-decoration: none;\"\u003e\n\u003cspan style=\"font-size:18px;\"\u003e\u003cstrong\u003e· \u003c\/strong\u003e\u003c\/span\u003eAutomatic Mains Failure sequence\u003c\/li\u003e\n\t\u003cli style=\"box-sizing: border-box; margin: 0px 0px 4px 10px; padding: 0px 0px 0px 3px; position: relative; font-size: 16px; color: rgb(67, 67, 67); text-decoration: none;\"\u003e\n\u003cspan style=\"font-size:18px;\"\u003e\u003cstrong\u003e· \u003c\/strong\u003e\u003c\/span\u003eComplies with: VDE AR-N 4110 (medium voltage, Germany), VDE AR-N 4105 (low voltage, Germany), EN 50549-1:2019 (Europe), ENA EREC G99 (United Kingdom). Option A10 required.\u003c\/li\u003e\n\t\u003cli style=\"box-sizing: border-box; margin: 0px 0px 4px 10px; padding: 0px 0px 0px 3px; position: relative; font-size: 16px; color: rgb(67, 67, 67); text-decoration: none;\"\u003e\n\u003cspan style=\"font-size:18px;\"\u003e\u003cstrong\u003e· \u003c\/strong\u003e\u003c\/span\u003eApproved by TÜV and UL\u003c\/li\u003e\n\t\u003cli style=\"box-sizing: border-box; margin: 0px 0px 4px 10px; padding: 0px 0px 0px 3px; position: relative; font-size: 16px; color: rgb(67, 67, 67); text-decoration: none;\"\u003e\n\u003cspan style=\"font-size:18px;\"\u003e\u003cstrong\u003e· \u003c\/strong\u003e\u003c\/span\u003eTier 4 final support\u003c\/li\u003e\n\t\u003cli style=\"box-sizing: border-box; margin: 0px 0px 4px 10px; padding: 0px 0px 0px 3px; position: relative; font-size: 16px; color: rgb(67, 67, 67); text-decoration: none;\"\u003e\n\u003cspan style=\"font-size:18px;\"\u003e\u003cstrong\u003e· \u003c\/strong\u003e\u003c\/span\u003eHot standby for full system redundancy– change to backup genset controller on the fly\u003c\/li\u003e\n\t\u003cli style=\"box-sizing: border-box; margin: 0px 0px 4px 10px; padding: 0px 0px 0px 3px; position: relative; font-size: 16px; color: rgb(67, 67, 67); text-decoration: none;\"\u003e\n\u003cspan style=\"font-size:18px;\"\u003e\u003cstrong\u003e· \u003c\/strong\u003e\u003c\/span\u003eRedundant CANbus for power management\u003c\/li\u003e\n\t\u003cli style=\"box-sizing: border-box; margin: 0px 0px 4px 10px; padding: 0px 0px 0px 3px; position: relative; font-size: 16px; color: rgb(67, 67, 67); text-decoration: none;\"\u003e\n\u003cspan style=\"font-size:18px;\"\u003e\u003cstrong\u003e· \u003c\/strong\u003e\u003c\/span\u003eClose Before Excitation\/Run-up synchronization\u003cspan style=\"font-size:18px;\"\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/span\u003e– synchronisation from 6 seconds\u003c\/li\u003e\n\t\u003cli style=\"box-sizing: border-box; margin: 0px 0px 4px 10px; padding: 0px 0px 0px 3px; position: relative; font-size: 16px; color: rgb(67, 67, 67); text-decoration: none;\"\u003e\n\u003cspan style=\"font-size:18px;\"\u003e\u003cstrong\u003e· \u003c\/strong\u003e\u003c\/span\u003eFully compatible with AGC 150 and AGC 200 controllers\u003c\/li\u003e\n\t\u003cli style=\"box-sizing: border-box; margin: 0px 0px 0px 10px; padding: 0px 0px 0px 3px; position: relative; font-size: 16px; color: rgb(67, 67, 67); text-decoration: none;\"\u003e\n\u003cspan style=\"font-size:18px;\"\u003e\u003cstrong\u003e· \u003c\/strong\u003e\u003c\/span\u003eSuitable for hybrid power solutions fitted with ASC-4 controllers \u003cspan style=\"font-size:16px;\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n","brand":"PEMP Generator Parts Store","offers":[{"title":"Default Title","offer_id":57470301929638,"sku":"AGC-4","price":3950.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0659\/1125\/9302\/files\/Sf2bce9a728b84039aebe8d6f12a6fc51K.webp?v=1726826681","url":"https:\/\/www.pempstore.com\/products\/original-deif-agc-4-repalce-by-agc-4-mkii-automatic-genset-controller-genset-control-module","provider":"PEMP Generator Parts Store","version":"1.0","type":"link"}