{"title":"Marathon","description":null,"products":[{"product_id":"original-marathon-generator-avr-dvr2000e-alternator-automatic-voltage-regulator-stabilizer-genset-accessories","title":"Original Marathon Generator AVR DVR2000E Alternator Automatic Voltage Regulator Stabilizer Genset Accessories","description":"\u003cp\u003e\u003cspan style=\"font-size:24px\"\u003e\u003cstrong\u003eOriginal Marathon Generator AVR DVR2000E Alternator Automatic Voltage Regulator Stabilizer Genset Accessories\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n \n\n\u003cp align=\"start\" style='font-family:\"Futura PT Book\";font-size:21.3333px;font-weight:400;letter-spacing:normal;line-height:1.80556vw;text-align:start;white-space:normal;color:rgb(79, 74, 74);background-color:rgb(255, 255, 255);margin:0px 0px 2.08333vw;margin-bottom:2.08333vw;margin-top:0px;margin-left:0px;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:border-box'\u003e\u003cspan style=\"font-size:16px\"\u003eThe \u003c\/span\u003e\u003cspan style=\"font-size:16px\"\u003e\u003cstrong\u003eMarathon DVR®2000E voltage regulator\u003c\/strong\u003e\u003c\/span\u003e\u003cspan style=\"font-size:16px\"\u003e is an electronic, solid state, microprocessor-based control device. The Automatic Voltage Regulator regulates the output voltage of a brushless, ac generator by controlling the current into the generator exciter field. Input power to the DVR2000E is from a multi-pole, high-frequency, permanent magnet generator (PMG).\u003c\/span\u003e\u003c\/p\u003e\n\n\u003ch3 align=\"start\" style='font-family:\"Futura PT\";font-size:1.73611vw;font-weight:400;letter-spacing:0.25px;text-align:start;white-space:normal;color:rgb(85, 85, 85);background-color:rgb(255, 255, 255);margin:0px 0px 20px;margin-bottom:20px;margin-top:0px;margin-left:0px;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:border-box'\u003e\u003cspan style=\"font-size:16px\"\u003eMarathon DVR2000E Voltage Regulator Features and Capabilities:\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003cul align=\"start\" style='font-family:\"Futura PT\";font-size:21.3333px;font-weight:500;letter-spacing:normal;text-align:start;white-space:normal;color:rgb(85, 85, 85);background-color:rgb(255, 255, 255);margin:0px 0px 20px 20px;margin-bottom:20px;margin-top:0px;margin-left:20px;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:border-box'\u003e\n\t\u003cli style=\"margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:border-box\"\u003e\n\t\u003cp\u003eFour control modes: \u003c\/p\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003col align=\"start\" style='font-family:\"Futura PT\";font-size:21.3333px;font-weight:500;letter-spacing:normal;text-align:start;white-space:normal;color:rgb(85, 85, 85);background-color:rgb(255, 255, 255);margin:0px 0px 20px 20px;margin-bottom:20px;margin-top:0px;margin-left:20px;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:border-box'\u003e\n\t\u003cli\u003e\n\t\u003col style=\"margin:0px 0px 0px 1.2rem;margin-bottom:0px;margin-top:0px;margin-left:1.2rem;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:border-box\"\u003e\n\t\t\u003cli style=\"margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:border-box\"\u003e\n\t\t\u003cp\u003eAutomatic Voltage Regulation (AVR)\u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\t\u003cli style=\"margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:border-box\"\u003e\n\t\t\u003cp\u003eManual or Field Current Regulation (FCR)\u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\t\u003cli style=\"margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:border-box\"\u003e\n\t\t\u003cp\u003ePower Factor Regulation (PF) \u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\t\u003cli style=\"margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:border-box\"\u003e\n\t\t\u003cp\u003eReactive Power Regulation (VAR)\u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\u003c\/ol\u003e\n\t\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003cul align=\"start\" style='font-family:\"Futura PT\";font-size:21.3333px;font-weight:500;letter-spacing:normal;text-align:start;white-space:normal;color:rgb(85, 85, 85);background-color:rgb(255, 255, 255);margin:0px 0px 20px 20px;margin-bottom:20px;margin-top:0px;margin-left:20px;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:border-box'\u003e\n\t\u003cli style=\"margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:border-box\"\u003e\n\t\u003cp\u003eProgrammable stability settings\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli style=\"margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:border-box\"\u003e\n\t\u003cp\u003eSoft start control with an adjustable time setting in AVR control mode\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli style=\"margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:border-box\"\u003e\n\t\u003cp\u003eOverexcitation limiting (OEL) in AVR, VAR and PF control modes\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli style=\"margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:border-box\"\u003e\n\t\u003cp\u003eUnderfrequency (volts\/hertz) regulation\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli style=\"margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:border-box\"\u003e\n\t\u003cp\u003eCrowbar circuitry protects the field\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli style=\"margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:border-box\"\u003e\n\t\u003cp\u003eOvertemperature protection\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli style=\"margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:border-box\"\u003e\n\t\u003cp\u003eThree-phase or single-phase generator voltage (RMS) sensing\/regulation in AVR mode\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli style=\"margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:border-box\"\u003e\n\t\u003cp\u003eSingle-phase generator current sensing for metering and regulation purposes\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli style=\"margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:border-box\"\u003e\n\t\u003cp\u003eField current and voltage sensing\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli style=\"margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:border-box\"\u003e\n\t\u003cp\u003eFour contact sensing inputs for system interface\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli style=\"margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:border-box\"\u003e\n\t\u003cp\u003eOne common output relay for alarm indication and trip functions\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli style=\"margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:border-box\"\u003e\n\t\u003cp\u003eSix protection functions \u003c\/p\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003col align=\"start\" style='font-family:\"Futura PT\";font-size:21.3333px;font-weight:500;letter-spacing:normal;text-align:start;white-space:normal;color:rgb(85, 85, 85);background-color:rgb(255, 255, 255);margin:0px 0px 20px 20px;margin-bottom:20px;margin-top:0px;margin-left:20px;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:border-box'\u003e\n\t\u003cli\u003e\n\t\u003col style=\"margin:0px 0px 0px 1.2rem;margin-bottom:0px;margin-top:0px;margin-left:1.2rem;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:border-box\"\u003e\n\t\t\u003cli style=\"margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:border-box\"\u003e\n\t\t\u003cp\u003eOverexcitation shutdown\u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\t\u003cli style=\"margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:border-box\"\u003e\n\t\t\u003cp\u003eGenerator overvoltage shutdown\u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\t\u003cli style=\"margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:border-box\"\u003e\n\t\t\u003cp\u003eDVR overtemperature shutdown\u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\t\u003cli style=\"margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:border-box\"\u003e\n\t\t\u003cp\u003eLoss of generator sensing shutdown\u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\t\u003cli style=\"margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:border-box\"\u003e\n\t\t\u003cp\u003eOverexcitation limiting \u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\t\u003cli style=\"margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:border-box\"\u003e\n\t\t\u003cp\u003eCrowbar shutdown\u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\u003c\/ol\u003e\n\t\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003cul align=\"start\" style='font-family:\"Futura PT\";font-size:21.3333px;font-weight:500;letter-spacing:normal;text-align:start;white-space:normal;color:rgb(85, 85, 85);background-color:rgb(255, 255, 255);margin:0px 0px 20px 20px;margin-bottom:20px;margin-top:0px;margin-left:20px;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:border-box'\u003e\n\t\u003cli style=\"margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:border-box\"\u003e\n\t\u003cp\u003eGenerator paralleling with reactive droop compensation and reactive differential compensation\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli style=\"margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:border-box\"\u003e\n\t\u003cp\u003eFront-panel human-machine interface (HMI) indicates system and DVR2000E status and gives the ability to make setting changes at the front panel\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli style=\"margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:border-box\"\u003e\n\t\u003cp\u003eRear RS-232 communication port for personal computer communication using MARATHON-DVR2000E-COMS Windows-based software for fast, user-friendly setup and control\u003c\/p\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cspan style=\"font-size:24px\"\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cdiv\u003e\u003cimg cke-id=\"img33\" referrerpolicy=\"no-referrer\" slate-data-type=\"image\" src=\"https:\/\/ae01.alicdn.com\/kf\/S6080bdb6663848b19c5fb56f8be8f0d5r.png\"\u003e\u003c\/div\u003e\u003cspan style=\"font-size:24px\"\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cdiv\u003e\u003cimg cke-id=\"img34\" referrerpolicy=\"no-referrer\" slate-data-type=\"image\" src=\"https:\/\/ae01.alicdn.com\/kf\/S284ed24cb7354c6496d6b3380a5c27dap.png\"\u003e\u003c\/div\u003e\u003cspan style=\"font-size:24px\"\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e\n","brand":"PEMP Generator Parts Store","offers":[{"title":"Default Title","offer_id":56656896000166,"sku":"DVR2000E","price":900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0659\/1125\/9302\/files\/S6080bdb6663848b19c5fb56f8be8f0d5r.webp?v=1726826104"},{"product_id":"original-marathon-dvr2400-digital-voltage-regulator-pmg-3-phase-rms-sensing-usb-modbus","title":"Original Marathon DVR2400 Digital Voltage Regulator PMG 3-Phase RMS Sensing USB Modbus","description":"\u003cspan style=\"font-size:22px;\"\u003e\u003cstrong\u003eOriginal Marathon DVR2400 Digital Voltage Regulator PMG 0.25% Regulation 3-Phase RMS Sensing USB Modbus\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\n \n\u003ch2\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/h2\u003e\n\n\u003cul style=\"list-style-type: disc;\"\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e: Marathon DVR2400 Digital Voltage Regulator\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e: \u003cspan style=\"font-size:16px;\"\u003eOriginal \u003c\/span\u003eMarathon\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e: Microprocessor digital AVR, PMG-excited\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eVoltage Regulation\u003c\/strong\u003e: ±0.25 % over load range at rated PF and constant frequency\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eTemperature Drift\u003c\/strong\u003e: ±0.0125 % \/ °C\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eOperating Power\u003c\/strong\u003e: 180–240 V AC, 250–300 Hz PMG, 350 VA\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eVoltage Sensing\u003c\/strong\u003e: 10–600 V AC, true RMS; 1-phase (AVR1) on 2400, selectable 3-phase (AVR3)\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eCurrent Sensing\u003c\/strong\u003e: 5 A AC continuous, 1-phase (B-phase) on 2400, optional CTs\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eRegulation Modes\u003c\/strong\u003e: AVR1, AVR3, FCR, VAR, PF\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eParalleling\u003c\/strong\u003e: Reactive droop compensation 0–10 % at rated kVAr; simulated reactive power\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eMetering\u003c\/strong\u003e: V, I, kW, kVA, kVAr, PF, Hz, field current (true RMS)\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e: USB 2.0 Modbus with DVRPortal software; front-panel HMI\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e: Field over\/under-excitation, gen over\/under-voltage, voltage imbalance, reverse power, loss of sensing, field over-current, regulator over-temperature, parallel faults\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e: 100% Original Marathon OEM\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e: 12 months genuine factory warranty\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"PEMP Generator Parts Store","offers":[{"title":"Default Title","offer_id":57701531254950,"sku":"DVR2400","price":1320.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0659\/1125\/9302\/files\/79bde8950b361f1a16c5d38cdc7c20e1.jpg?v=1792396082"}],"url":"https:\/\/www.pempstore.com\/collections\/marathon.oembed","provider":"PEMP Generator Parts Store","version":"1.0","type":"link"}